Knowledgebase Article 1033
|
|
Question:
|
How are the hydrotest rules of UG-99
applied to ANSI/ASME flanges?
|
|
Answer:
|
The UG-99 ratio does not apply to ASME B16.5/16.47
rated flanges. "Standard" ASME/ANSI
flanges are accepted as standard pressure
components per Section VIII Division 1 Paragraph
UG-44. The hydrotest rules for ASME B16.5/16.47
rated flanges from the ASME B16.5/16.47 standard
rather than the ASME Section VIII code.
ASME B16.5/16.47 does not use the pressure factor
approach. Instead, a specified method to calculate
the flange MAP permitted. In COMPRESS, this MAP
is listed with a "dummy" pressure
factor of 1.0.
ASME/ANSI flanges are excluded from UG-99 for
the same reason that they are excluded from
Appendix 2 calculations. Once the ASME/ANSI
rating standard has been invoked those provisions
may be used in lieu of the ASME Section VIII Code.
The pressure vessel code does not make any
provision for limiting the test pressure (UG-99
and UG-100) based on standard flanges and their
test pressure. COMPRESS alerts the designer when
the standard flanges may be overstressed at the
Section VIII test pressures.
(See http://www.codeware.com/support/faq/1056.html for discussion
of testing for flanges designed per Appendix 2)
|
|
|