Question:
|
Why can't I add user defined materials
for use in specifying ANSI/ASME flanges?
|
|
Answer:
|
For ASME/ANSI B16.5 and B16.47 flanges,
COMPRESS permits using only those materials
that are actually listed in these standards.
This restriction applies to long weld neck
flanges (LWN) and other "integral"
forgings where the standard flange is forged
integrally with the nozzle neck.
Materials for ASME/ANSI B16.5 and B16.47
flanges are contained in a database that is
separate from the ASME Section II materials
database. The flange database contains only
those materials listed in Tables 1A of the
flange standards. Materials cannot be added
to or removed from this database.
If a different material is approved by Code
Case or Interpretation for use under B16.5
or B16.47, select a listed material from the
same material group that the proposed material
would fall into. In this manner, the correct
pressure-temperature rating would be applied
in the COMPRESS model.
See related topic: http://www.codeware.com/support/faq/1164.html
|
|
|